{"id":3982,"date":"2024-02-22T11:03:46","date_gmt":"2024-02-22T11:03:46","guid":{"rendered":"https:\/\/reinmedical.com\/calibrazione-di-riferimento\/"},"modified":"2024-08-30T15:34:19","modified_gmt":"2024-08-30T15:34:19","slug":"calibrazione-di-riferimento","status":"publish","type":"post","link":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/","title":{"rendered":"Calibrazione di riferimento"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background fusion-parallax-none nonhundred-percent-fullwidth non-hundred-percent-height-scrolling lazyload gradient-container-1\" style=\"--awb-background-position:center top;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-min-height:543px;--awb-background-size:cover;--awb-flex-wrap:wrap;\" data-bg=\"https:\/\/reinmedical.com\/wp-content\/uploads\/2024\/02\/Unbenannt-4.2.jpg\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1248px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling gradient-container-2\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-background-color:var(--awb-color3);--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1248px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_4_5 4_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:80%;--awb-margin-top-large:0px;--awb-spacing-right-large:2.4%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:2.4%;--awb-width-medium:80%;--awb-order-medium:0;--awb-spacing-right-medium:2.4%;--awb-spacing-left-medium:2.4%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><h1>Calibrazione di riferimento<\/h1>\n<p>Trasferire l&#8217;immagine da un monitor all&#8217;altro<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_5 1_5 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:20%;--awb-margin-top-large:0px;--awb-spacing-right-large:9.6%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:9.6%;--awb-width-medium:20%;--awb-order-medium:0;--awb-spacing-right-medium:9.6%;--awb-spacing-left-medium:9.6%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling gradient-container-3\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1248px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-2\"><p>In nessun altro settore la visualizzazione precisa delle immagini \u00e8 cos\u00ec importante come nell&#8217;ambiente medico. Che si tratti di radiologia, chirurgia, cardiologia o ortopedia. Ci\u00f2 richiede monitor di alta qualit\u00e0 e ad alte prestazioni, in grado di visualizzare scale di grigio e colori in modo realistico e riproducibile. &#8220;I controller di visualizzazione con una LookUpTable 3D appositamente sviluppata da Rein Medical a questo scopo non solo hanno le relative preimpostazioni &#8211; come la maggior parte dei dispositivi della concorrenza &#8211; ma sono anche calibrati individualmente secondo le specifiche degli standard. Ogni dispositivo viene calibrato individualmente per ridurre le deviazioni dei colori e delle scale di grigio visualizzabili, legate alla produzione e ai componenti, a un minimo finora irraggiungibile (Delta E)&#8221;, spiega Andre Czollek del reparto sviluppo di Rein Medical, illustrando un vantaggio dei monitor.<\/p>\n<p>Sono stati introdotti degli standard per ottenere una presentazione standardizzata delle immagini. I pi\u00f9 noti per la rappresentazione del colore sono BT.709, BT.1886 e BT.2020.<\/p>\n<p>e lo standard DICOM per la visualizzazione in scala di grigi. &#8220;In linea di principio, vengono definite le coordinate cromatiche dei colori primari rosso, verde e blu, il punto di bianco per la massima luminosit\u00e0 e il gradiente di luminosit\u00e0 (gamma) nella gamma visibile all&#8217;uomo&#8221;, spiega Czollek. Per consentire la calibrazione del colore, questi valori della tabella di conversione vengono salvati nella LookUpTable (LUT) del controller del display. La dimensione della LUT \u00e8 determinante per il risultato e la qualit\u00e0. &#8220;Grazie alla nostra innovativa 3D LookUpTable nel controller del display, \u00e8 possibile realizzare un numero significativamente maggiore di gradazioni e quindi ottenere una visualizzazione molto pi\u00f9 precisa. Inoltre, i valori di luminosit\u00e0 vengono mantenuti costanti per l&#8217;intero ciclo di vita grazie alla stabilizzazione automatica della luminanza (ALS) integrata e offrono quindi un ulteriore aspetto di qualit\u00e0&#8221;, sottolinea Czollek.<\/p>\n<p>Il Delta E \u00e8 la differenza tra le specifiche degli standard e i valori effettivamente raggiunti dal monitor. Un delta E fino a 0,5 rappresenta una deviazione quasi impercettibile nelle distanze cromatiche, fino a un valore di 1,0 \u00e8 evidente a un occhio esperto, fino a un valore di distanza cromatica di 5,0 e oltre viene valutato come un colore diverso. Il CLINIO 432DCUH di Rein Medical raggiunge un Delta E di 0,5 avg. e un delta E di 0,7max. &#8220;I prodotti comparabili hanno un valore compreso tra 1,75 e 5,07, che non \u00e8 accettabile in questo intervallo critico&#8221;, avverte Czollek.<\/p>\n<p>L&#8217;esatta calibrazione dei monitor \u00e8 quindi la base per una visualizzazione precisa e coerente delle immagini. Con la calibrazione di riferimento, Rein Medical ha sviluppato un&#8217;altra procedura speciale con cui \u00e8 possibile copiare l&#8217;immagine familiare di un monitor esterno su monitor selezionati delle serie Rein Medical CLINIO e OPERION. &#8220;Questo rende possibile per la prima volta agli utenti di trasferire la propria immagine familiare su un dispositivo Rein Medical attuale. Con l&#8217;aiuto di uno speciale sensore, vengono letti tutti i parametri dello schermo esistente e i valori di riferimento ottenuti vengono trasferiti in modo permanente alla LUT 3D del monitor. Questo processo \u00e8 possibile sia nel nostro laboratorio presso la sede di M\u00f6nchengladbach che come servizio presso l&#8217;utente finale&#8221;, spiega Andre Czollek, illustrando la nuova tecnologia.<\/p>\n<\/div><div ><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-1 fusion-button-default-span fusion-button-default-type\" target=\"_self\" href=\"#\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">Maggiori informazioni su MEDIGENIC<\/span><\/a><\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":2454,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[111],"tags":[],"class_list":["post-3982","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-prodotti"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Calibrazione di riferimento - Rein Medical<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Calibrazione di riferimento - Rein Medical\" \/>\n<meta property=\"og:url\" content=\"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/\" \/>\n<meta property=\"og:site_name\" content=\"Rein Medical\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-22T11:03:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-08-30T15:34:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/reinmedical.com\/wp-content\/uploads\/2024\/02\/Unbenannt-4.2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"840\" \/>\n\t<meta property=\"og:image:height\" content=\"285\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"22 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/#\\\/schema\\\/person\\\/b1378b4bd1058be4cf876e1916a30174\"},\"headline\":\"Calibrazione di riferimento\",\"datePublished\":\"2024-02-22T11:03:46+00:00\",\"dateModified\":\"2024-08-30T15:34:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/\"},\"wordCount\":4496,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/reinmedical.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Unbenannt-4.2.jpg\",\"articleSection\":[\"Prodotti\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/\",\"url\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/\",\"name\":\"Calibrazione di riferimento - Rein Medical\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/reinmedical.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Unbenannt-4.2.jpg\",\"datePublished\":\"2024-02-22T11:03:46+00:00\",\"dateModified\":\"2024-08-30T15:34:19+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/#\\\/schema\\\/person\\\/b1378b4bd1058be4cf876e1916a30174\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/#primaryimage\",\"url\":\"https:\\\/\\\/reinmedical.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Unbenannt-4.2.jpg\",\"contentUrl\":\"https:\\\/\\\/reinmedical.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Unbenannt-4.2.jpg\",\"width\":840,\"height\":285},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/calibrazione-di-riferimento\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/casa\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Calibrazione di riferimento\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/\",\"name\":\"Rein Medical\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/#\\\/schema\\\/person\\\/b1378b4bd1058be4cf876e1916a30174\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5cea383344ba28565fe30ef941da2988d577fe8827a60cf8b7ad5c1ded27b701?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5cea383344ba28565fe30ef941da2988d577fe8827a60cf8b7ad5c1ded27b701?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5cea383344ba28565fe30ef941da2988d577fe8827a60cf8b7ad5c1ded27b701?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"http:\\\/\\\/wp.hannas-makramee.de\"],\"url\":\"https:\\\/\\\/reinmedical.com\\\/it\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Calibrazione di riferimento - Rein Medical","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/","og_locale":"it_IT","og_type":"article","og_title":"Calibrazione di riferimento - Rein Medical","og_url":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/","og_site_name":"Rein Medical","article_published_time":"2024-02-22T11:03:46+00:00","article_modified_time":"2024-08-30T15:34:19+00:00","og_image":[{"width":840,"height":285,"url":"https:\/\/reinmedical.com\/wp-content\/uploads\/2024\/02\/Unbenannt-4.2.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"admin","Tempo di lettura stimato":"22 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/#article","isPartOf":{"@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/"},"author":{"name":"admin","@id":"https:\/\/reinmedical.com\/it\/#\/schema\/person\/b1378b4bd1058be4cf876e1916a30174"},"headline":"Calibrazione di riferimento","datePublished":"2024-02-22T11:03:46+00:00","dateModified":"2024-08-30T15:34:19+00:00","mainEntityOfPage":{"@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/"},"wordCount":4496,"commentCount":0,"image":{"@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/#primaryimage"},"thumbnailUrl":"https:\/\/reinmedical.com\/wp-content\/uploads\/2024\/02\/Unbenannt-4.2.jpg","articleSection":["Prodotti"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/","url":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/","name":"Calibrazione di riferimento - Rein Medical","isPartOf":{"@id":"https:\/\/reinmedical.com\/it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/#primaryimage"},"image":{"@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/#primaryimage"},"thumbnailUrl":"https:\/\/reinmedical.com\/wp-content\/uploads\/2024\/02\/Unbenannt-4.2.jpg","datePublished":"2024-02-22T11:03:46+00:00","dateModified":"2024-08-30T15:34:19+00:00","author":{"@id":"https:\/\/reinmedical.com\/it\/#\/schema\/person\/b1378b4bd1058be4cf876e1916a30174"},"breadcrumb":{"@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/#primaryimage","url":"https:\/\/reinmedical.com\/wp-content\/uploads\/2024\/02\/Unbenannt-4.2.jpg","contentUrl":"https:\/\/reinmedical.com\/wp-content\/uploads\/2024\/02\/Unbenannt-4.2.jpg","width":840,"height":285},{"@type":"BreadcrumbList","@id":"https:\/\/reinmedical.com\/it\/calibrazione-di-riferimento\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/reinmedical.com\/it\/casa\/"},{"@type":"ListItem","position":2,"name":"Calibrazione di riferimento"}]},{"@type":"WebSite","@id":"https:\/\/reinmedical.com\/it\/#website","url":"https:\/\/reinmedical.com\/it\/","name":"Rein Medical","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/reinmedical.com\/it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Person","@id":"https:\/\/reinmedical.com\/it\/#\/schema\/person\/b1378b4bd1058be4cf876e1916a30174","name":"admin","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/secure.gravatar.com\/avatar\/5cea383344ba28565fe30ef941da2988d577fe8827a60cf8b7ad5c1ded27b701?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/5cea383344ba28565fe30ef941da2988d577fe8827a60cf8b7ad5c1ded27b701?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5cea383344ba28565fe30ef941da2988d577fe8827a60cf8b7ad5c1ded27b701?s=96&d=mm&r=g","caption":"admin"},"sameAs":["http:\/\/wp.hannas-makramee.de"],"url":"https:\/\/reinmedical.com\/it\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/posts\/3982","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/comments?post=3982"}],"version-history":[{"count":0,"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/posts\/3982\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/media\/2454"}],"wp:attachment":[{"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/media?parent=3982"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/categories?post=3982"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/reinmedical.com\/it\/wp-json\/wp\/v2\/tags?post=3982"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}