{"id":4458,"date":"2024-01-18T07:24:35","date_gmt":"2024-01-18T07:24:35","guid":{"rendered":"https:\/\/reinmedical.com\/quality-assurance-for-image-reproduction-devices\/"},"modified":"2024-08-30T15:37:08","modified_gmt":"2024-08-30T15:37:08","slug":"quality-assurance-for-image-reproduction-devices","status":"publish","type":"page","link":"https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/","title":{"rendered":"Quality assurance for image reproduction devices"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background fusion-parallax-none nonhundred-percent-fullwidth non-hundred-percent-height-scrolling lazyload gradient-container-1\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-min-height:500px;--awb-background-size:cover;--awb-flex-wrap:wrap;\" data-bg=\"https:\/\/reinmedical.com\/wp-content\/uploads\/2024\/01\/header-s-1600.jpg\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-align-content-center fusion-flex-content-wrap\" style=\"max-width:1248px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-1\"><h1 style=\"text-align: center;\"><span style=\"color: #ffffff;\">Quality assurance for image reproduction devices<\/span><\/h1>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling gradient-container-2\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:50px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1248px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-2\"><p>Detailed information on acceptance and constancy testing In order to meet the high requirements of diagnostic reporting, a number of basic principles have been developed in Germany to ensure that the image display systems (AAS) used meet these high quality standards.<br \/>\nAt the same time, control bodies have been appointed to ensure that the framework conditions created for quality assurance are also implemented.   <\/p>\n<h2>ACCEPTANCE AND CONSTANCY TEST<\/h2>\n<p>  To ensure proper installation and configuration of the AOPD, an acceptance test of the AOPD must be carried out by the manufacturer or supplier in accordance with X-ray Ordinance (R\u00f6V) \u00a716.<br \/>\nAmong other things, this involves checking whether the image display unit (AOPD) is controlled at the correct resolution and whether the required reference values are complied with in accordance with the declared room class and the diagnostic method.<br \/>\nSubsequently, visual or metrological tests, so-called constancy tests, must be carried out at regular, defined intervals.<br \/>\nThis is carried out by expert personnel of the operator or by a service provider such as Rein Medical GmbH.<br \/>\nOptional: we will be happy to inform you about training opportunities at your \/ our premises.      <\/p>\n<h2>STANDARDS, GUIDELINES, ETC.<\/h2>\n<p>  There are different catalogs of requirements for ESPE.<br \/>\nThe following regulations must be taken into account for quality assurance: DIN 6868-157:2014-11, which regulates the performance of the acceptance test of the ESPE, is a German standard from November 2014 which replaces DIN-V 6868-57:2001-02 for initial commissioning and new acceptance tests of diagnostic monitors, supplements it with requirements for the constancy test and adapts it to the state of the art.<br \/>\nAn important part of quality assurance is the consideration of environmental conditions.<br \/>\nIt is not only direct and indirect light sources that must be taken into account during the acceptance test.<br \/>\nIn contrast to DIN-V 6868-57, which is no longer permitted for new acceptance tests as of 01.05.2015, there is no longer a distinction between categories (Cat. A \/ Cat. B. \/ mammography) but a division into room classes with corresponding requirements (see table) These room classes (RK 1-6) are divided into &#8211; AAS with diagnostic quality &#8211; AAS with viewing quality &nbsp; An AAS is made up of several components (hardware and software), which are documented during the acceptance test.<br \/>\nIf one of these components is replaced or the software version of the PACS or operating system is changed, a partial acceptance test \/ comparison measurement must be carried out to ensure that the change does not affect the image quality.<br \/>\nIn addition, the scope of application in dentistry is now also regulated in DIN 6868-157.<br \/>\nFor the acceptance test, it is necessary, among other things, that the test images specified in DIN 6868-157 can be displayed from the application software (in most cases your PACS software) in the native resolution of the BWG.<br \/>\nSince a negative influence on the display of the test images when using different software cannot generally be ruled out, the manufacturer or supplier must either carry out the tests in the application software during the acceptance test or ensure an identical display, e.g. by means of a comparative measurement between the application and QA software.<br \/>\nThis serves the uniform approach of DIN 6868-157 to include all components that can have a quality-relevant influence on the quality of the findings in quality assurance.<br \/>\nThe Quality Assurance Guideline (QA Guideline) is currently being revised due to the changes introduced by DIN 6868-157.<br \/>\nIt regulates the practical implementation of the constancy test in accordance with DIN-V 6868-57, which applies to monitors accepted before May 1, 2015, as well as the constancy test in accordance with DIN 6868-157 in the revised version.             <\/p>\n<h2>A LOOK AT OTHER COUNTRIES<\/h2>\n<p>  Even though Germany plays a leading role in the implementation and design of quality assurance at national level in Europe, there are other countries that also call for the implementation of quality assurance of BWG.<br \/>\nThe &#8220;American Association of Physicists in Medicine (AAPM)&#8221; and the report of &#8220;Task Group 18 (TG18)&#8221;, which is part of the AAPM, can be seen as one of the most important pioneers in quality assurance.<br \/>\nThe &#8220;Quality assurance guideline for medical imaging display systems&#8221; of the &#8220;Japan Industries Association of Radiological Systems Standards (JESRA)&#8221; is also strongly based on this description of quality assurance.<br \/>\nOther countries that have also implemented quality assurance are usually based on the AAPM or the DIN V 6868-57 template, such as the Swiss &#8220;Directive R &#8211; 08 &#8211; 06&#8221; issued by the Federal Office of Public Health.     <\/p>\n<h2>MINIMUM REQUIREMENTS FOR PICTURE DISPLAY DEVICES ACCORDING TO DIN 6868-157<\/h2>\n<h1 style=\"text-align: center;\"><span style=\"color: #ffffff;\">Imprint and disclaimer<\/span><\/h1>\n<\/div>\n<table class=\"table table-striped\">\n<thead>\n<tr>\n<th>Body region \/ method<\/th>\n<th>Lmax in cd\/m\u00b2<\/th>\n<th>Lmin in cd\/m\u00b2<\/th>\n<th>Maximum luminance ratio<\/th>\n<th>Resolution (w) x Pixel (h)<\/th>\n<th>Luminance characteristic<\/th>\n<th>Homogeneity within BWG (between several BWG)<\/th>\n<th>adequate device from JVC<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Projection radiography (thorax, skeleton, abdomen)<\/td>\n<td class=\"text-nowrap\">\u2265 250<\/td>\n<td class=\"text-nowrap\"><\/td>\n<td class=\"text-nowrap\">\u2265 250<\/td>\n<td class=\"text-nowrap\">\u2265 1 600 \u00d7 \u2265 1 200<\/td>\n<td class=\"text-nowrap\">GSDF \u00b1 10 %<\/td>\n<td class=\"text-nowrap\">&lt;  25 % (&lt; 20 %)<\/td>\n<td>CCL214, CCL258i2, CCL358i2, CCL650i2, ME205, MS25i2, MS35i2, CL-S200, CL-S300 CL-S600<\/td>\n<\/tr>\n<tr>\n<td>Fluoroscopy, all applications<\/td>\n<td class=\"text-nowrap\">\u2265 150<\/td>\n<td class=\"text-nowrap\"><\/td>\n<td class=\"text-nowrap\">\u2265 100<\/td>\n<td class=\"text-nowrap\">\u2265 1 024 \u00d7 \u2265 1 024<\/td>\n<td class=\"text-nowrap\">GSDF \u00b1 15 %<\/td>\n<td class=\"text-nowrap\">&lt;  25 % (&lt; 20 %)<\/td>\n<td>CCL214 CCL258i2, MS25i2, ME205, CL-S200, CL-S300<\/td>\n<\/tr>\n<tr>\n<td>Computer tomography<\/td>\n<td class=\"text-nowrap\">\u2265 150<\/td>\n<td class=\"text-nowrap\"><\/td>\n<td class=\"text-nowrap\">\u2265 100<\/td>\n<td class=\"text-nowrap\">\u2265 1 024 \u00d7 \u2265 1 024<\/td>\n<td class=\"text-nowrap\">GSDF \u00b1 15 %<\/td>\n<td class=\"text-nowrap\">&lt;  25 % (&lt; 20 %)<\/td>\n<td>CCL214, CCL258i2, MS25i2, ME205, CL-S200<\/td>\n<\/tr>\n<tr>\n<td>For RK 5: Dental digital volume tomography, intraoral X-ray diagnostics with dental tube devices, panoramic tomography, cephalometric radiographs of the skull, dental skull overview radiographs, hand radiographs to determine skeletal growth<\/td>\n<td class=\"text-nowrap\">\u2265 200<\/td>\n<td class=\"text-nowrap\">\u2265 1.1 \u00d7 Lamb<\/td>\n<td class=\"text-nowrap\">\u2265 100<\/td>\n<td class=\"text-nowrap\">\u2265 1 024 \u00d7 \u2265 768<\/td>\n<td class=\"text-nowrap\">Not applicable *2<\/td>\n<td class=\"text-nowrap\">&lt;  30 % (&lt; 30 %)<\/td>\n<td>CCL214, CCL258i2, MS25i2, ME205, CL-S200 MS-S200<\/td>\n<\/tr>\n<tr>\n<td>For RK 6: Intraoral X-ray diagnostics with dental tube devices, panoramic tomographs, cephalometric radiographs of the skull, dental skull overview radiographs, hand radiographs to determine skeletal growth<\/td>\n<td class=\"text-nowrap\">\u2265 300<\/td>\n<td class=\"text-nowrap\"><\/td>\n<td class=\"text-nowrap\">\u2265 100<\/td>\n<td class=\"text-nowrap\">\u2265 1 024 \u00d7 \u2265 768<\/td>\n<td class=\"text-nowrap\">Not applicable *2<\/td>\n<td class=\"text-nowrap\">&lt;  30 % (&lt; 30 %)<\/td>\n<td>CCL214, CCL258i2, MS25i2, ME205, CL-S200 MS-S200<\/td>\n<\/tr>\n<tr>\n<td class=\"text-nowrap\">Mammography<\/td>\n<td class=\"text-nowrap\">\u2265 250<\/td>\n<td class=\"text-nowrap\"><\/td>\n<td class=\"text-nowrap\">\u2265 250<\/td>\n<td class=\"text-nowrap\">\u2265 2 048 \u00d7 \u2265 2 048<\/td>\n<td class=\"text-nowrap\">GSDF \u00b1 10 %<\/td>\n<td class=\"text-nowrap\">&lt;  25 % (&lt; 10 %)<\/td>\n<td>MS55i2plus, CCL550i2 CL-S500 MS-S500 CL-S1200<\/td>\n<\/tr>\n<tr>\n<td>Mammographic stereotaxy<\/td>\n<td class=\"text-nowrap\">\u2265 200<\/td>\n<td class=\"text-nowrap\"><\/td>\n<td class=\"text-nowrap\">\u2265 100<\/td>\n<td class=\"text-nowrap\">\u2265 1 024 \u00d7 \u2265 1 024<\/td>\n<td class=\"text-nowrap\">GSDF \u00b1 15 %<\/td>\n<td class=\"text-nowrap\">&lt;  25 % (&lt; 20 %)<\/td>\n<td>CCL214, CCL258i2, MS25i2, ME205, CL-S200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"100-width.php","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-4458","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Quality assurance for image reproduction devices - Rein Medical<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Quality assurance for image reproduction devices - Rein Medical\" \/>\n<meta property=\"og:url\" content=\"https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/\" \/>\n<meta property=\"og:site_name\" content=\"Rein Medical\" \/>\n<meta property=\"article:modified_time\" content=\"2024-08-30T15:37:08+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"15 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/en\\\/quality-assurance-for-image-reproduction-devices\\\/\",\"url\":\"https:\\\/\\\/reinmedical.com\\\/en\\\/quality-assurance-for-image-reproduction-devices\\\/\",\"name\":\"Quality assurance for image reproduction devices - Rein Medical\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/en\\\/#website\"},\"datePublished\":\"2024-01-18T07:24:35+00:00\",\"dateModified\":\"2024-08-30T15:37:08+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/reinmedical.com\\\/en\\\/quality-assurance-for-image-reproduction-devices\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/reinmedical.com\\\/en\\\/quality-assurance-for-image-reproduction-devices\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/en\\\/quality-assurance-for-image-reproduction-devices\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/reinmedical.com\\\/en\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Quality assurance for image reproduction devices\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/reinmedical.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/reinmedical.com\\\/en\\\/\",\"name\":\"Rein Medical\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/reinmedical.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Quality assurance for image reproduction devices - Rein Medical","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/","og_locale":"en_US","og_type":"article","og_title":"Quality assurance for image reproduction devices - Rein Medical","og_url":"https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/","og_site_name":"Rein Medical","article_modified_time":"2024-08-30T15:37:08+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"15 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/","url":"https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/","name":"Quality assurance for image reproduction devices - Rein Medical","isPartOf":{"@id":"https:\/\/reinmedical.com\/en\/#website"},"datePublished":"2024-01-18T07:24:35+00:00","dateModified":"2024-08-30T15:37:08+00:00","breadcrumb":{"@id":"https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/reinmedical.com\/en\/quality-assurance-for-image-reproduction-devices\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/reinmedical.com\/en\/home\/"},{"@type":"ListItem","position":2,"name":"Quality assurance for image reproduction devices"}]},{"@type":"WebSite","@id":"https:\/\/reinmedical.com\/en\/#website","url":"https:\/\/reinmedical.com\/en\/","name":"Rein Medical","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/reinmedical.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/reinmedical.com\/en\/wp-json\/wp\/v2\/pages\/4458","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/reinmedical.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/reinmedical.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/reinmedical.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/reinmedical.com\/en\/wp-json\/wp\/v2\/comments?post=4458"}],"version-history":[{"count":0,"href":"https:\/\/reinmedical.com\/en\/wp-json\/wp\/v2\/pages\/4458\/revisions"}],"wp:attachment":[{"href":"https:\/\/reinmedical.com\/en\/wp-json\/wp\/v2\/media?parent=4458"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}